PCB / SMT Inspection Lab
Watch Xiaoxi Inspect a PCB
Compare selected areas at native resolution. OpenCV runs locally to identify differences, and optional AI reviews color crops and summarizes its observations.
CAD import and placement setup
Import a KiCad PCB file
Supports common KiCad 6–9 files and KiCad 10 format 20260206. Reads SMT designators, positions, rotation and Courtyard or Fab boundaries with pads locally. Raw CAD stays in your browser. Schematics, standalone footprints, Altium, ODB++, IPC-2581, Gerber and 3D files are unsupported.
Choose a .kicad_pcb file (up to 10 MB and 2,000 footprints).
View parsed CAD details (generated boxes use 0°; original angle shown separately)
| Designator | Value | Board side | Original angle | Box center X / Y (mm) | Box width / height (mm) | Footprint |
|---|
Import replaces the placement and footprint CSV data and clears the four calibration points. Existing component boxes stay until you apply a preview. Skipped and unparsed footprints are listed.
Import KiCad or CSV data, calibrate four points, preview and apply boxes, then verify them and save the setup JSON. Component dimensions must be supplied or parsed from the CAD file.
Data formats and coordinate rules
Use millimeters and component center coordinates. Positive rotation runs from +X toward +Y. At 0°, width follows X and height follows Y. Keep the original axes and use four matching points to map to the image. Blank side defaults to top. Calibrate each board side separately.
Include the component body and pads in the dimensions. Supply width and height per row or use a footprint size table. Padding adds millimeters on each side. Have engineering verify designators, angles, polarity and acceptance criteria.
Export these CSV fields from your PCB design or placement system. This step uses placement coordinates and dimensions.
Four-point CAD-to-photo calibration
Choose four distinct points near the board perimeter, such as fiducial or mounting-hole centers. Enter their CAD X and Y in clockwise or counterclockwise order, then select the matching points on the reference image or enter pixel coordinates. This maps the board plane and does not calibrate physical measurements.
CAD calibration is not configured.
Preview box coordinates
| Designator | X px | Y px | Width (px) | Height (px) |
|---|
Missing dimensions, invalid boxes and overlaps block the batch. Each applied box is one review unit. AI reviews up to 12 positions per batch.
Inspection recipe and customer inputs
Use approved BOMs, drawings, datasheets and quality standards. Inputs are exported with results and can guide AI review. Verify part identity, polarity and tolerances separately.
BOM and component placement
English or Chinese headers are supported. Export UTF-8 CSV from Excel. Use one designator per row, up to 500 rows.
| Designator | Part number | Footprint | X mm | Y mm | Angle (°) | Polarity | Notes |
|---|
The recipe is held in page memory. Download it to keep it. AI review sends relevant recipe details and local image crops when enabled.
Which inputs affect inspection?
- Used in comparison: native pixel area, alignment, thresholds, minimum difference area, edge tolerance and scan direction.
- When scale and minimum feature size are both provided, the tool requires at least five pixels per feature. Calibrate the scale first.
- BOM, placement, polarity, tolerance text, capture notes and reviewer details support documentation and review. Verify acceptance manually.
- Validate results on real boards. This page cannot verify component electrical values or continuity.
2. Inspection and thresholds
Check that the binary image isolates the intended traces. Pads, silkscreen, glare and solder can affect results. Verify rotation and polarity using visible markings or explicit annotations.
Enter polarity notes in the BOM and mark the full component with the same designator. Boxes must fit inside the ROI. Specified components are reviewed even without a detected difference. Each batch uses existing AI credits and covers up to 12 positions. The report lists uncovered positions. Personnel make hold, scrap and release decisions.
Whole-board mode uses the applied component boxes and native pixels. Capture both images in a fixed fixture or align them beforehand. Results list visible differences and skipped positions by designator.
AI review summary
AI review has not run.
Inspection locations and color comparison
Reference: region location
Aligned test image: region location
Reference crop: review area in yellow
Test crop: review area in yellow
The map shows the inspection area. X and Y refer to the original reference image. Switching regions displays existing results without rerunning inspection or AI review.
Advanced: local differences, evidence and parameters
3. Results and evidence
Ready to run.
Reference ROI at native resolution
Aligned test image and candidate boxes
Reference binary / edge map
Test binary / edge map
Results identify visible difference candidates for review. Electrical faults and whole-board acceptance require separate verification. Validate capture resolution, missed detections and false alarms on real boards.
Would this work for your board?
Have an operator review the trial results. Setup for one board revision starts at NT$30,000–50,000 depending on sides, checks and validation scope. Usage, hardware and PLC or MES integration are quoted separately.
Request a board evaluation →Production Line Integration Consultation
Planning to integrate SmartQC into your production line? Leave your contact details so we can discuss board types, inspection requirements, cycle time, and equipment integration.